BISOPE series 5-General method for naming vibration measuring
points (measuring points)
------------------------------------------------------------
----------------------------------------------
In order
to effectively measure vibration and perform predictive maintenance, it is
necessary to find and set the correct measurement point and store the measured
data continuously. A defect in equipment is usually found at the point where
vibration shows the highest amplitude, and this may have directionality or may
be a point that directly expresses the cause. It is a diagnosis. However, the first starting point for this diagnosis is to name the
measurement point, and we will check the internationally common naming
method.
Measurement point selection rules
If data measurement points are marked on equipment, data are collected from the same location, so trend data has reliability first. The measuring points should be the same as those called on the instrument (route) or on the recording paper (computer file). For example, if the ‘horizontal direction of the motor half-load side’ was measured and saved by the measuring instrument, there would be a way to easily recognize this point and express it simply.
All copyright korea CBM written by
BISOPE , vs72@naver.com, 070-4388-0415, www.kCBM.kr